Low Resistance Measuring Instrument - Company Ranking(4 companyies in total)
Last Updated: Aggregation Period:Jul 09, 2025〜Aug 05, 2025
This ranking is based on the number of page views on our site.
Display Company Information
Company Name | Featured Products | ||
---|---|---|---|
Product Image, Product Name, Price Range | overview | Application/Performance example | |
![]() Ultra Low Resistance Meter / AE-1152D
100,000 yen-500,000 yen |
■ Ideal for ultra-low resistance measurement of shunt resistors, etc. ■ Cancellation measurement of thermoelectric voltage effects ■ Pulsed measurement current to reduce self-heating and wear on measurement terminals ■ Standard contact check function ■ Absolute measurement: 0.0000mΩ to 1.5000kΩ ■ Percentage measurement: 0.1mΩ to 1kΩ / ±50.00% [Minimum resolution 10nΩ] ■ GP-IB / RS-232C / Centronics interface (optional) ■ Comparator results available as open collector output, LED display, and buzzer sound ■ Standard equipped with measurement current/voltage abnormality check circuit ■ Shift output available | The ability to cancel out "thermoelectric voltage," which has a significant impact on the measurement of ultra-low resistance represented by shunt resistors, enables high-precision measurements. Additionally, it is equipped with a "contact check function" that monitors the contact state of each terminal in the essential four-terminal measurement for low resistance, achieving more reliable measurements. This has been widely adopted to meet various ultra-low resistance measurement needs, including those of resistor manufacturers. | |
![]() Ultra-Low Resistance Meter / AE-1152F
100,000 yen-500,000 yen |
■% Measurement: 0.01mΩ~1kΩ/±50.00%【Minimum resolution 1nΩ】 ■Absolute Value Measurement: 0.0000mΩ~1.5000kΩ ■Ideal for ultra-low resistance measurements such as shunt resistors ■Cancellation measurement of thermoelectric effects ■Measurement current applied in pulses to reduce self-heating and wear on measurement terminals ■Contact check function standard equipped ■GP-IB / RS-232C / Centronics interface (optional) ■Comparator results available as open collector output, LED display, and buzzer sound ■Measurement current/voltage abnormality check circuit standard equipped ■Shift output available | By canceling out the "thermoelectric voltage," which has a significant impact on the measurement of ultra-low resistance represented by shunt resistors, it is now possible to achieve high-precision measurements. Additionally, the standard equipment includes a "contact check function" that monitors the contact state of each terminal in the essential four-terminal measurement for low resistance, ensuring more reliable measurements. This has been widely adopted to meet various ultra-low resistance measurement needs, including those of resistor manufacturers. Minimum measurement resolution: 1 nΩ. | |
---
--- |
--- |
-
- Featured Products
-
Ultra Low Resistance Meter / AE-1152D
- overview
- ■ Ideal for ultra-low resistance measurement of shunt resistors, etc. ■ Cancellation measurement of thermoelectric voltage effects ■ Pulsed measurement current to reduce self-heating and wear on measurement terminals ■ Standard contact check function ■ Absolute measurement: 0.0000mΩ to 1.5000kΩ ■ Percentage measurement: 0.1mΩ to 1kΩ / ±50.00% [Minimum resolution 10nΩ] ■ GP-IB / RS-232C / Centronics interface (optional) ■ Comparator results available as open collector output, LED display, and buzzer sound ■ Standard equipped with measurement current/voltage abnormality check circuit ■ Shift output available
- Application/Performance example
- The ability to cancel out "thermoelectric voltage," which has a significant impact on the measurement of ultra-low resistance represented by shunt resistors, enables high-precision measurements. Additionally, it is equipped with a "contact check function" that monitors the contact state of each terminal in the essential four-terminal measurement for low resistance, achieving more reliable measurements. This has been widely adopted to meet various ultra-low resistance measurement needs, including those of resistor manufacturers.
Ultra-Low Resistance Meter / AE-1152F
- overview
- ■% Measurement: 0.01mΩ~1kΩ/±50.00%【Minimum resolution 1nΩ】 ■Absolute Value Measurement: 0.0000mΩ~1.5000kΩ ■Ideal for ultra-low resistance measurements such as shunt resistors ■Cancellation measurement of thermoelectric effects ■Measurement current applied in pulses to reduce self-heating and wear on measurement terminals ■Contact check function standard equipped ■GP-IB / RS-232C / Centronics interface (optional) ■Comparator results available as open collector output, LED display, and buzzer sound ■Measurement current/voltage abnormality check circuit standard equipped ■Shift output available
- Application/Performance example
- By canceling out the "thermoelectric voltage," which has a significant impact on the measurement of ultra-low resistance represented by shunt resistors, it is now possible to achieve high-precision measurements. Additionally, the standard equipment includes a "contact check function" that monitors the contact state of each terminal in the essential four-terminal measurement for low resistance, ensuring more reliable measurements. This has been widely adopted to meet various ultra-low resistance measurement needs, including those of resistor manufacturers. Minimum measurement resolution: 1 nΩ.
-
Membership (free) is required to view all content.