We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Low Resistance Measuring Instrument.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Low Resistance Measuring Instrument - Company Ranking(4 companyies in total)

Last Updated: Aggregation Period:Jul 09, 2025〜Aug 05, 2025
This ranking is based on the number of page views on our site.

Company Name Featured Products
Product Image, Product Name, Price Range overview Application/Performance example
■ Ideal for ultra-low resistance measurement of shunt resistors, etc. ■ Cancellation measurement of thermoelectric voltage effects ■ Pulsed measurement current to reduce self-heating and wear on measurement terminals ■ Standard contact check function ■ Absolute measurement: 0.0000mΩ to 1.5000kΩ ■ Percentage measurement: 0.1mΩ to 1kΩ / ±50.00% [Minimum resolution 10nΩ] ■ GP-IB / RS-232C / Centronics interface (optional) ■ Comparator results available as open collector output, LED display, and buzzer sound ■ Standard equipped with measurement current/voltage abnormality check circuit ■ Shift output available The ability to cancel out "thermoelectric voltage," which has a significant impact on the measurement of ultra-low resistance represented by shunt resistors, enables high-precision measurements. Additionally, it is equipped with a "contact check function" that monitors the contact state of each terminal in the essential four-terminal measurement for low resistance, achieving more reliable measurements. This has been widely adopted to meet various ultra-low resistance measurement needs, including those of resistor manufacturers.
■% Measurement: 0.01mΩ~1kΩ/±50.00%【Minimum resolution 1nΩ】 ■Absolute Value Measurement: 0.0000mΩ~1.5000kΩ ■Ideal for ultra-low resistance measurements such as shunt resistors ■Cancellation measurement of thermoelectric effects ■Measurement current applied in pulses to reduce self-heating and wear on measurement terminals ■Contact check function standard equipped ■GP-IB / RS-232C / Centronics interface (optional) ■Comparator results available as open collector output, LED display, and buzzer sound ■Measurement current/voltage abnormality check circuit standard equipped ■Shift output available By canceling out the "thermoelectric voltage," which has a significant impact on the measurement of ultra-low resistance represented by shunt resistors, it is now possible to achieve high-precision measurements. Additionally, the standard equipment includes a "contact check function" that monitors the contact state of each terminal in the essential four-terminal measurement for low resistance, ensuring more reliable measurements. This has been widely adopted to meet various ultra-low resistance measurement needs, including those of resistor manufacturers. Minimum measurement resolution: 1 nΩ.
---

---

---
  1. Featured Products
    Ultra Low Resistance Meter / AE-1152DUltra Low Resistance Meter / AE-1152D
    overview
    ■ Ideal for ultra-low resistance measurement of shunt resistors, etc. ■ Cancellation measurement of thermoelectric voltage effects ■ Pulsed measurement current to reduce self-heating and wear on measurement terminals ■ Standard contact check function ■ Absolute measurement: 0.0000mΩ to 1.5000kΩ ■ Percentage measurement: 0.1mΩ to 1kΩ / ±50.00% [Minimum resolution 10nΩ] ■ GP-IB / RS-232C / Centronics interface (optional) ■ Comparator results available as open collector output, LED display, and buzzer sound ■ Standard equipped with measurement current/voltage abnormality check circuit ■ Shift output available
    Application/Performance example
    The ability to cancel out "thermoelectric voltage," which has a significant impact on the measurement of ultra-low resistance represented by shunt resistors, enables high-precision measurements. Additionally, it is equipped with a "contact check function" that monitors the contact state of each terminal in the essential four-terminal measurement for low resistance, achieving more reliable measurements. This has been widely adopted to meet various ultra-low resistance measurement needs, including those of resistor manufacturers.
    Ultra-Low Resistance Meter / AE-1152FUltra-Low Resistance Meter / AE-1152F
    overview
    ■% Measurement: 0.01mΩ~1kΩ/±50.00%【Minimum resolution 1nΩ】 ■Absolute Value Measurement: 0.0000mΩ~1.5000kΩ ■Ideal for ultra-low resistance measurements such as shunt resistors ■Cancellation measurement of thermoelectric effects ■Measurement current applied in pulses to reduce self-heating and wear on measurement terminals ■Contact check function standard equipped ■GP-IB / RS-232C / Centronics interface (optional) ■Comparator results available as open collector output, LED display, and buzzer sound ■Measurement current/voltage abnormality check circuit standard equipped ■Shift output available
    Application/Performance example
    By canceling out the "thermoelectric voltage," which has a significant impact on the measurement of ultra-low resistance represented by shunt resistors, it is now possible to achieve high-precision measurements. Additionally, the standard equipment includes a "contact check function" that monitors the contact state of each terminal in the essential four-terminal measurement for low resistance, ensuring more reliable measurements. This has been widely adopted to meet various ultra-low resistance measurement needs, including those of resistor manufacturers. Minimum measurement resolution: 1 nΩ.